Skip to content

Struct OpenSkyhawk::AnalogConfig

ClassList > OpenSkyhawk > AnalogConfig

Tuning for an AnalogInput . Every field has a default, so a sketch sets only what differs, by name:{ .hysteresis = 32, .ewmaShift = 4, .pollMs = 2 } (#295).More...

  • #include <AnalogInput.h>

Public Attributes

Type Name
uint8_t ewmaShift = [**DEFAULT\_EWMA\_SHIFT**](structOpenSkyhawk_1_1AnalogConfig.md#variable-default_ewma_shift)
uint16_t hysteresis = [**HYSTERESIS\_AUTO**](structOpenSkyhawk_1_1AnalogConfig.md#variable-hysteresis_auto)
Output counts of movement required before a new value is emitted (HYSTERESIS_AUTO: by route).
uint16_t maxRaw = 65535
Raw ADC value mapping to 65535. Readings above are clamped.
uint16_t minRaw = 0
Raw ADC value mapping to 0. Readings below are clamped.
uint16_t pollMs = [**DEFAULT\_POLL\_MS**](structOpenSkyhawk_1_1AnalogConfig.md#variable-default_poll_ms)
bool reverse = false
false: minRaw → 0, maxRaw → 65535. true: inverted.

Public Static Attributes

Type Name
constexpr uint16_t DCS_HYSTERESIS = 1024
DCS-BIOS route: 1024 keeps a sweep from flooding DCS-BIOS import (SoakRig and E2E use it).
constexpr uint8_t DEFAULT_EWMA_SHIFT = 3
EWMA α = 1/2^3 = 1/8.
constexpr uint16_t DEFAULT_POLL_MS = 8
default min interval between ADC reads (ms).
constexpr uint16_t HID_HYSTERESIS = 128
HID route: 128 — the value the axis calibration was validated with (#46/#251).
constexpr uint16_t HYSTERESIS_AUTO = 0xFFFF
constexpr uint8_t MAX_EWMA_SHIFT = 15
cap: scaled<<shift must fit int32 at full scale.

Detailed Description

Fields are only ever appended, each with a default, so a new setting never breaks a sketch. The constants are the defaults and limits the fields refer to.

Public Attributes Documentation

variable ewmaShift

uint8_t OpenSkyhawk::AnalogConfig::ewmaShift;

EWMA smoothing strength: α = 1/2^ewmaShift. Capped to MAX_EWMA_SHIFT — beyond that the int32 accumulator (scaled << shift) would overflow at full scale.


variable hysteresis

Output counts of movement required before a new value is emitted (HYSTERESIS_AUTO: by route).

uint16_t OpenSkyhawk::AnalogConfig::hysteresis;


variable maxRaw

Raw ADC value mapping to 65535. Readings above are clamped.

uint16_t OpenSkyhawk::AnalogConfig::maxRaw;


variable minRaw

Raw ADC value mapping to 0. Readings below are clamped.

uint16_t OpenSkyhawk::AnalogConfig::minRaw;


variable pollMs

uint16_t OpenSkyhawk::AnalogConfig::pollMs;

Min interval between ADC reads, ms. Per instance, not per node. Not clamped: 0 means read every loop iteration, which is legal but makes τ track the loop rate — not a controlled quantity. An ADS1115 PinRef blocks ~8 ms per conversion whatever this says, so keep those at the default or higher.


variable reverse

false: minRaw → 0, maxRaw → 65535. true: inverted.

bool OpenSkyhawk::AnalogConfig::reverse;


Public Static Attributes Documentation

variable DCS_HYSTERESIS

DCS-BIOS route: 1024 keeps a sweep from flooding DCS-BIOS import (SoakRig and E2E use it).

constexpr uint16_t OpenSkyhawk::AnalogConfig::DCS_HYSTERESIS;


variable DEFAULT_EWMA_SHIFT

EWMA α = 1/2^3 = 1/8.

constexpr uint8_t OpenSkyhawk::AnalogConfig::DEFAULT_EWMA_SHIFT;


variable DEFAULT_POLL_MS

default min interval between ADC reads (ms).

constexpr uint16_t OpenSkyhawk::AnalogConfig::DEFAULT_POLL_MS;


variable HID_HYSTERESIS

HID route: 128 — the value the axis calibration was validated with (#46/#251).

constexpr uint16_t OpenSkyhawk::AnalogConfig::HID_HYSTERESIS;


variable HYSTERESIS_AUTO

constexpr uint16_t OpenSkyhawk::AnalogConfig::HYSTERESIS_AUTO;

hysteresis default: chosen from the controlId's route when the input is constructed — DCS_HYSTERESIS for a DCSIN_* (DCS-BIOS) id, HID_HYSTERESIS for a CTRL_* (HID) id. Any other value is used as given.


variable MAX_EWMA_SHIFT

cap: scaled<<shift must fit int32 at full scale.

constexpr uint8_t OpenSkyhawk::AnalogConfig::MAX_EWMA_SHIFT;



The documentation for this class was generated from the following file Firmware/Libraries/PanelGroup/Inputs/AnalogInput/AnalogInput.h