Debugging on STM32
Two things tell you what an STM32 board is doing: the DiagSerial debug stream and the bi-color status LED. Neither touches the DCS data path, so you can watch a board in isolation. This page covers both, plus the bench gotchas that cost the most time.
DiagSerial — the debug stream
Every STM32 board exposes a debug UART, standard across the project:
| Setting | Value |
|---|---|
| Peripheral | USART1 (Serial1) |
| Pins | PA9 (TX) / PA10 (RX) |
| Baud | 115200 |
| Header | 3-pin (GND / RX / TX) on every board |
Connect a USB-to-TTL adapter to the 3-pin header and open a serial monitor at 115200
(pio device monitor). Enable output by calling STM32Board::setDebug(true) in setup();
production builds leave it false (default) — the pins stay available but silent. Keep it off in a
flying cockpit: every log line waits for the 115200-baud UART, so a board with it on handles only a
few hundred inputs a second. The templates and panel sketches ship with it off.
USART1 is used because PanelBridge already uses UART2 (Serial, PA2/PA3) for the RP2040 link —
the two never conflict.
The status LED
Each custom OpenSkyhawk STM32 board has a bi-color red/green LED on fixed pins (PB14 = red,
PB15 = green), initialised automatically by STM32Board::begin(). Read the board's state at
a glance:
| LED | Meaning |
|---|---|
| Off | Not powered |
| Red blinking | Booting / initialising |
| Green blinking | Normal — CAN healthy, no data flowing |
| Green solid | Connected — CAN healthy and data flowing (DCS exports on PanelBridge; CTRL_BCAST on PanelGroup) |
| Red fast blink | TEC > 0 — transmit errors accumulating |
| Red solid | Bus-off — CAN controller halted |
| Red / green alternating | Warning / degraded state |
The state machine is shared (STM32Board); only the triggers differ per role. Green solid
(connected) appears while data is actively flowing and decays back to green-blinking after
~½ s of quiet. Warning (red/green alternating) means a tracked PanelGroup node died (PanelBridge), the
master heartbeat was lost (any node other than PanelBridge), or the board's clock failed to lock (any STM32
node — see below). On PanelBridge it clears when the node comes back, when its node ID is changed by a
firmware update (the old ID is forgotten automatically), or when the client is told to forget a board
that was removed on purpose.
In the bootloader: red and green together
The running firmware never lights both LEDs at once. When red and green are on together, the board is in its bootloader, not running its firmware:
| LEDs | Meaning |
|---|---|
| Red + green blinking together (1 Hz) | Waiting for an update — asked for one, caught at power-up, or its firmware is missing or broken |
| Red + green flickering together (fast) | A firmware update is being written |
| Red + green, alternating with red alone | The firmware kept resetting before it finished booting — the bootloader stopped starting it until it's updated |
| Red + green, alternating with green alone | A new board with no node number yet — waiting for its first firmware |
CAN faults are driven from the CanStatus callback. For non-CAN faults (dead node, lost
master, SYNC timeout, I²C hang), the firmware calls STM32Board::setWarning(true) and clears
it with setWarning(false) on recovery.
One warning source outranks all others: a clock fault. If SystemClock_Config can't lock
the 72 MHz HSE tree (dead crystal, cold joint, or an inconsistent config), STM32Board latches
it, falls back to internal RC, and drives the warning pattern at top precedence — above CAN faults — so a
bad clock isn't misdiagnosed as a bus problem. A clock-faulted node also comes up CAN
listen-only (never transmits at the wrong rate). Latched once at boot (query
STM32Board::clockFault()); begin() logs
CLOCK OK/FAULT: SYSCLK=.. PCLK1=.. CAN=..bps ADC=..kHz on DiagSerial. This detects a missing/dead crystal, not a wrong-value one. See issue #245 /
Design Decisions.
PB14/PB15 are reserved
The status-LED pins are owned by STM32Board — don't use PB14/PB15 for panel I/O or
MCP23017 interrupts. PC13/PC14/PC15 are also off-limits on custom boards.
The Gateway's link counters
The Gateway's RP2040 has no debug UART. Instead, it keeps link-health counters you can read over its USB serial port: UART errors by kind, lines dropped, and how often it reconnected USB or rebooted itself, plus when the first UART error and the first USB loss happened. Close the OpenSkyhawk Client, then:
tools/simgw_bench/simgw_bench.py diag /dev/cu.usbmodem1101
What the counters mean, and how the Gateway recovers its own USB link, is on the SimGateway page.
Bench gotchas
ST-Link won't upload or connect
Old probe firmware ("only supports deprecated HLA") or a clone's non-standard tap ID ("tap not found") — see Flashing → ST-Link troubleshooting.
Don't use STM32 USB CDC for DCS-BIOS
Enabling STM32 native USB CDC (PIO_FRAMEWORK_ARDUINO_ENABLE_CDC) and running DCS-BIOS
traffic over it crashes the port consistently — it becomes unusable until replug. This
is the whole reason the SimGateway exists. Use UART; let
the RP2040 handle USB. (Also: USB and CAN share PA11/PA12 and can't both be active.)
- Don't remap
SerialtoSerial1via#define Serial Serial1— it causes "multiple definition of Serial2" or runtime failures depending on the STM32duino version. With no CDC flag,Serialmaps to UART2 (PA2/PA3) natively, which is what PanelBridge uses for the RP2040 link.