Skip to content

File PduNode.h

FileList > Firmware > Libraries > PowerMonitor > PduNode.h

Go to the source code of this file

PDU monitoring node — the whole node in two calls (#216). More...

  • #include <stdint.h>
  • #include <STM32Board.h>
  • #include <CANProtocol.h>
  • #include "RailMonitor.h"
  • #include "BoardThermal.h"
  • #include "PduCalStore.h"

Namespaces

Type Name
namespace PduNode

Detailed Description

A PDU sketch is just:

#include <PduNode.h>
void setup() { STM32Board::setDebug(true); PduNode::setup(); }
void loop()  { PduNode::loop(); }
with -DNODE_ID=N in platformio.ini. What runs: * Node status — HB_n / HEALTH_n (board kind PDU, #344) / master-loss watchdog via CANProtocol::serviceNodeStatus(). Rail and thermal faults reach HEALTH_n.faultId through the FaultSource registry. * Sampling — the four rail channels every PDU_SAMPLE_US (1 kHz target); the NTC and Vrefint every 100 ms. Faults are held clear for PDU_BOOT_BLANK_MS after boot. * Telemetry — one TELEM_n frame per second, rotating PDU_RAIL_12V → PDU_RAIL_5V → PDU_STATUS; a page whose flags change goes out at once (≤ 1 per 100 ms per page); SYNC_REQ sends all three pages immediately. * Calibration — DiagSerial (115200) commands, one per line: CAL SHOW · CAL VDDA <mV> (DMM reading of the 3V3 rail) · CAL ZERO (no load connected) · CAL CLEAR · RAW (live readings + scan rate). Stored per board in the reserved flash page (PduCalStore).

Rail faults are reported to the host only (TELEM_n flags + HEALTH_n.faultId). The status LEDs follow every other node — CAN / link state plus the master-loss WARNING — and don't change for rail faults (FirmwarePlan D14). The board's power LEDs (D3 12 V / D4 5 V / D5 3V3) are passive, wired to their rails, and show rail presence only — this firmware never drives them.

Copyright:

GPL-2.0-only — see Firmware/LICENSE


The documentation for this class was generated from the following file Firmware/Libraries/PowerMonitor/PduNode.h